Service Philosophy
天迈始终坚持高品质服务客户,服务流程贯穿技术研发、质检、生产、售后服务整个体系。
天迈坚信:做产品的本质不仅仅是解决问题,更重要的是站在客户的角度去思考问题,为客户提升效益,携手共进;
天迈的高品质不仅仅体现在理念先行,更加落实在行动之间,完善的金牌服务流程以及专业的服务人员是最基本的保障。
Tianmai always adheres to providing high-quality services for customers, with service procedures covering the entire system of R&D, quality inspection, production and after-sales service.
Tianmai firmly believes that the essence of product manufacturing is not merely solving problems. More importantly, we think from customers' perspective to improve their benefits and achieve common development.
Tianmai’s high quality is reflected not only in advanced concepts, but also in practical actions. The complete gold-standard service procedures and professional service personnel serve as the fundamental guarantee.
Pulse Controller Malfunction
Check whether the controller indicates each contact /check the output of each terminal.
Incorrect Setting of the Pulse Jet System
Increase pulse jet frequency / Low compressed air pressure; raise pressure, inspect the dryer and clean it if necessary, check for blockages in pipelines.
Main Causes and Troubleshooting for Low Fan Motor Current / Low Air Volume
- High differential pressure of the dust collector.
- Reversed installation of fan and motor pulleys: Refer to drawings and reinstall the pulleys correctly.
- Pipeline blockage due to dust accumulation: Clean the pipeline and check the gas flow velocity.
- Fan damper closed: Open the damper and lock it in the open position.
- Dust collector poppet valve closed: Inspect the air circuit and open the valve plate.
- Excessively high system static pressure: Measure static pressure at both ends of the fan and verify against design specifications, adjust as required. Check pipelines for high flow velocity and replace the original defective design.
- Fan operating outside design requirements: Inspect the fan inlet structure to ensure stable airflow. Check blades for wear, repair or replace as needed.
- Fan reverse rotation: Reverse the wiring connections on the motor.
Excessive Secondary Dust Re-entrainment
Drain the hopper continuously; perform ash cleaning for each row of filter bags/cartridges in a random sequence instead of sequential cleaning. Inspect the inlet baffle and ensure it is clean.
Pulse Jet Valve Malfunction
Check the diaphragm valve /inspect the control solenoid valve.
Incorrect Differential Pressure Reading
Clean the pressure tap /inspect the air tube for cracks /check the differential pressure gauge.
Filter Bag Clogging
Condensation on filter bags (see below); send the filter bags to the laboratory for cause analysis.
Dry and ash-clean the filter bags, or replace them, reduce air volume, increase compressed air pressure, raise ash cleaning frequency, and inject neutral conditioning powder to form a protective layer and porous loose primary cake.